CFR Roof™ - Composite CFR

CFR Composite

1. Rigid Insulation
Insulation must be field coped at all backup plates (ridge, high side, and endlaps). This will allow the roof to float & prevent stress at endlaps. Rigid insulation thickness = 2” minimum and 4” maximum. Insulation not by Nucor.
2. Liner Decking
Liner decking is .6C 28 gage painted white, and is fabricated in accordance with SDI specifications and tolerances. Nucor does not offer warranties on liner decking.
3. Clip Fastener
Two (2) required per clip; the fastener must engage roof structural members. Self-drilling  fastener without washer is utilized.
NOTE: Nucor recommends the liner decking and roof structural members to be pre-drilled for the clip fasteners to help avoid fastener drill point breakage.
4. Deck Fastener
Standard fasteners are self-drilling fasteners without washers. Puddle welds are an available option for joists only. Spacing shall be as follows unless specified differently be design:
12” o.c. at intermediate supports
6” o.c. at endlap-s
30” o.c. at sidelaps
5. UL90 Rated System Member Spacing
Maximum purlin spacing shall be 5’-0”.
Maximum joist spacing shall be 5’-0”.
6. Vapor Barrier
Vapor barrier is required in all composite “CFR”™ applications to help avoid problems  with condensation. Vapor barrier is not provided by Nucor Building Systems.

More detailed Information is available by clicking on any of the links listed below:

Main CFR™ Page Details Specifications Seaming Options
Translucent Panel Single Curb Manual Double Curb Manual Clip/Insulation Options

 

 

Seneca Steel

975 E. Main St • Logan, OH 43138 • 800-853-8225 • Local: 740-385-0517
E-mail


Home | Services | Products | About Us | Quote | Testimonials | Projects | Search | Site Map | Feedback

© 2003-2007 Seneca Steel Erectors, Inc. , All Right Reserved
Website Design by Green & Associates